Goodwe Error Codes
Expert reference guide covering all Goodwe inverter diagnostic codes with comprehensive troubleshooting procedures and professional repair guidance
Quickly identify problems with your Goodwe solar system and learn the correct response procedures
Goodwe Inverter Models
Goodwe produces an extensive lineup of premium inverter systems for residential and commercial solar installations. The GW series represents standard inverter technology with high efficiency, while HT series models provide high-voltage solutions for larger installations. EH series offers hybrid inverters with battery integration. These diagnostic codes are applicable to the majority of Goodwe inverter systems sold in the United States. Error indicators typically manifest as numeric error codes on the inverter display, LED status indicators, and status messages in the SEMS monitoring portal.
How to Read Error Codes
- • Check inverter display for error code numbers (e.g., 01, 02, 03, 07, 12, 102, 108, 120, 302)
- • Review LED status indicators on inverter
- • Check SEMS portal for system status messages
- • Note error code format and any additional information
- • Consult Goodwe documentation for your specific model
Goodwe Product Series
- • GW Series - Standard high-efficiency inverters
- • HT Series - High-voltage inverters for large systems
- • EH Series - Hybrid inverters with battery integration
- • Data Logger - System monitoring and communication
- • SEMS Portal - Cloud-based monitoring platform
Understanding Diagnostic Codes
Goodwe inverter systems incorporate sophisticated diagnostic capabilities that automatically detect operational issues. When a problem is identified, the system communicates through numeric error codes displayed on the inverter, LED status indicators, and status messages in the SEMS monitoring portal. This intelligent diagnostic framework enables rapid problem identification and helps determine the appropriate response. All Goodwe inverter series (GW, HT, EH) utilize continuous performance monitoring with real-time error detection. Error codes are typically numeric (e.g., 01, 02, 03, 07, 12, 25, 102, 108, 120, 302) that indicate specific system conditions or faults. Always reference your specific model's installation manual for precise code definitions.
Internal Communication and System Errors
Problems with internal communication and system components.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 01 | SPI Error - Internal communication error |
|
|
| 02 | EEPROM R/W Error - Memory chip error |
|
|
| 12 | LCD Communication Error - Communication error between LCD-DSP and Master-DSP |
|
|
Grid Connection Errors
Problems with AC grid voltage, frequency, and connection.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 03 | Grid Frequency Error - Grid frequency exceeds inverter limit |
|
|
| 102 | Grid Frequency Out of Range - Grid frequency outside allowable range |
|
|
| 108 | Grid Voltage Fluctuation - Voltage fluctuations in grid |
|
|
| Grid Voltage Out of Range | Grid voltage outside allowable range |
|
|
| Grid Disconnected | System has lost connection to utility grid |
|
|
DC Voltage and Isolation Errors
Problems with DC input voltage and electrical isolation.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| DC Overvoltage | DC input voltage exceeds maximum limit |
|
|
| DC Undervoltage | DC input voltage below minimum operating threshold |
|
|
| 120 | Isolation Test Failed - Isolation test failed |
|
|
| Isolation Fault | Isolation error detected between PV system and ground |
|
|
Relay and Hardware Errors
Problems with relay operation and hardware components.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 07 | Relay Self-Test Error - Error in relay self-test |
|
|
| 25 | Relay Self-Test Error - Error in relay self-test |
|
|
Communication and Monitoring Errors
Problems with external communication and monitoring systems.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 302 | Smart Meter Communication Error - Communication problem between inverter and Smart Meter |
|
|
| Data Logger Communication Error | Inverter cannot communicate with data logger |
|
|
| SEMS Portal Not Accessible | SEMS monitoring portal not accessible or showing errors |
|
|
Temperature and Overheating Errors
Problems with inverter temperature and thermal protection.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| Overtemperature | Inverter temperature exceeds maximum limit |
|
|
| Temperature Sensor Error | Temperature sensor fault or communication error |
|
|
Internal Inverter Errors
Problems with inverter internal systems and hardware.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| Internal Inverter Error | Internal inverter fault or hardware error |
|
|
| Power Stage Error | Inverter power stage fault |
|
|
Critical Safety Notice
Do not attempt DIY repairs on your Goodwe solar system. The majority of diagnostic codes relate to high-voltage DC and AC electrical systems, grid connection safety mechanisms, or critical safety features. Specific codes requiring immediate professional intervention include: 120 (Isolation Test Failed), Isolation Fault, and Power Stage Error. Upon encountering these codes, immediately shut down the system if safe to do so and contact a certified Goodwe installer without delay.
Professional service is mandatory—contact a licensed solar installer or reach out to Goodwe technical support for expert assistance.
Maintenance Guidelines
Scheduled Service Requirements
- ✓Professional inspection and service annually by certified Goodwe installer
- ✓Monthly visual inspection of solar panels for damage or soiling
- ✓Clean panels quarterly or as needed based on local conditions
- ✓Monitor system performance daily through SEMS portal
- ✓Check inverter status and LED indicators monthly
- ✓Verify data logger is online and communicating
Proactive Maintenance Strategies
- ✓Keep panels clean to maximize energy production
- ✓Trim trees and vegetation to prevent shading
- ✓Ensure adequate ventilation around inverter
- ✓Monitor production trends for early problem detection
- ✓Keep firmware updated for latest features and fixes
- ✓Review system alerts and error codes promptly
Frequently Asked Questions
What does error code 01 (SPI Error) mean?
Error code 01 indicates an internal communication error. Disconnect grid output and DC input switches, wait 5 minutes, and reconnect both switches. If the problem is not resolved, contact your dealer or customer service. This may require professional diagnosis.
What does error code 03 (Grid Frequency Error) mean?
Error code 03 indicates that the grid frequency exceeds the inverter limit. Check current grid frequency and verify it is within allowable limits. Wait for grid frequency to stabilize. The inverter will automatically reconnect when frequency returns to normal. Contact the utility company if frequency is consistently out of range.
What should I do if I see error code 120 (Isolation Test Failed)?
Error code 120 indicates that the isolation test failed. Do not attempt to start the system. Inspect all PV modules for physical damage, check all DC connections and junction boxes, test isolation resistance, and check for water ingress. This is a serious safety condition. Contact a certified installer to perform isolation testing.
What does error code 302 (Smart Meter Communication Error) mean?
Error code 302 indicates a communication problem between the inverter and Smart Meter. Check communication wiring between inverter and smart meter, verify smart meter is powered and online, check Modbus communication settings, test communication connection, and restart inverter if needed. Contact an installer if communication cannot be restored.
What should I do if I see error code 07 or 25 (Relay Self-Test Error)?
Error codes 07 and 25 indicate an error in relay self-test. Disconnect grid output and DC input switches, wait 5 minutes, and reconnect both switches. If the problem is not resolved, contact your dealer or customer service. The relay may need to be replaced.
Can I repair my Goodwe system myself?
High-voltage DC and AC electrical work must exclusively be performed by licensed professionals to ensure safety compliance. Homeowners can safely perform basic tasks like cleaning panels and monitoring the SEMS portal, but all technical repairs require certified Goodwe installers. Unauthorized work on electrical systems poses extreme danger and violates building codes.
What does error code 108 (Grid Voltage Fluctuation) mean?
Error code 108 indicates voltage fluctuations in the grid. Check grid voltage stability, verify voltage is within allowable limits, wait for grid voltage to stabilize, contact the utility company if voltage fluctuations persist, and contact an installer if the problem continues.
How often should I clean my solar panels?
Solar panels should be cleaned quarterly or as needed based on local conditions. Panels in dusty areas or areas with heavy pollen may need more frequent cleaning. Keep panels clean to maximize energy production. Inspect panels monthly for damage or excessive soiling that may require immediate cleaning.
Need Additional Help?
Search our complete knowledge base to find detailed solutions for your specific problem.
Go to Knowledge BaseSummary
Proper interpretation of diagnostic codes is essential for effective Goodwe solar system troubleshooting. This comprehensive reference enables quick problem identification and guides appropriate response actions. Goodwe systems utilize numeric error codes displayed on inverter displays, LED status indicators, and status messages in the SEMS monitoring portal to indicate specific sensor and system malfunctions. GW, HT, and EH series inverters provide diagnostic information through error codes and monitoring systems for convenient diagnosis.
⚠️Complex diagnostic situations, especially those involving high-voltage DC and AC electrical systems and grid connection safety, require immediate professional evaluation. Critical codes demanding urgent response include: 120 (Isolation Test Failed), Isolation Fault, and Power Stage Error. These indicators represent serious safety hazards requiring certified Goodwe installer response. Adherence to scheduled maintenance protocols and immediate attention to diagnostic codes extends equipment service life and minimizes long-term operational costs. Note that error code formats may vary by model and firmware version—always consult your specific unit's installation and service manual for precise interpretations.