- Brivis Braemar MagIQtouch error code 56 signifies a flame sensing failure, which can hinder the proper functioning of your heating system. This failure primarily arises from issues with the flame sensor, interruptions in the gas supply, or problems with the electronic control board. Additionally, a dirty flame sensor can lead to inaccurate readings, prompting the system to shut down as a safety measure to prevent potential hazards.
- To effectively address this error, follow these detailed troubleshooting steps:
- 1. **Safety First**: Before beginning any maintenance, ensure your safety by turning off the power to the heating unit at the circuit breaker. This will prevent any electrical shock or accidental activation of the system.
- 2. **Locate the Flame Sensor**: Open the access panel of your Braemar MagIQtouch unit to find the flame sensor. It is usually positioned near the burner assembly.
- 3. **Disconnect Wiring**: Carefully disconnect the wiring harness connected to the flame sensor. This step is crucial to avoid damaging any wires during the cleaning process.
- 4. **Remove the Flame Sensor**: Using a screwdriver, gently remove the flame sensor from its mounting bracket. Take care not to disturb any other components in the vicinity, as they may be delicate or sensitive.
- 5. **Clean the Flame Sensor**: Using fine steel wool or a soft cloth, clean the flame sensor thoroughly to remove any carbon deposits or dirt. A clean sensor is vital for accurate flame detection, as accumulated soot can lead to false readings.
- 6. **Reinstall the Flame Sensor**: Once cleaned, carefully reinstall the flame sensor back into its original position, ensuring it is securely mounted and that no components are misaligned.
- 7. **Reconnect Wiring**: Reattach the wiring harness to the flame sensor, ensuring that the connections are tight and secure. Loose connections can lead to intermittent faults or future errors.
- 8. **Check for Gas Leaks**: Before restoring power, it is essential to verify that there are no gas leaks around the burner assembly or flame sensor area. Use a gas leak detector or soap solution to check for bubbles that indicate a leak.