SMA Solar Technology Error Codes
Expert reference guide covering all SMA Sunny Boy inverter diagnostic codes with comprehensive troubleshooting procedures and professional repair guidance
Quickly identify problems with your SMA solar system and learn the correct response procedures
SMA Inverter Models
SMA Solar Technology produces an extensive lineup of premium inverter systems for residential and commercial solar installations. The Sunny Boy series represents single-phase inverter technology with high efficiency and reliability, while Sunny Tripower models provide three-phase solutions for larger installations. These diagnostic codes are applicable to the majority of SMA inverter systems sold in the United States. Error indicators typically manifest as numeric error codes on the inverter display, LED status indicators, and status messages in the Sunny Portal monitoring system.
How to Read Error Codes
- • Check inverter display for numeric error codes (e.g., 33, 39, 102, 202, 301)
- • Review LED status indicators on inverter
- • Check Sunny Portal for system status messages
- • Note error code number and any additional information
- • Consult SMA documentation for your specific model
SMA Product Series
- • Sunny Boy - Single-phase high-efficiency inverters
- • Sunny Tripower - Three-phase inverters for larger systems
- • Sunny Central - Large-scale central inverters
- • Data Logger - System monitoring and communication
- • Sunny Portal - Cloud-based monitoring platform
Understanding Diagnostic Codes
SMA inverter systems incorporate sophisticated diagnostic capabilities that automatically detect operational issues. When a problem is identified, the system communicates through numeric error codes displayed on the inverter, LED status indicators, and status messages in the Sunny Portal monitoring system. This intelligent diagnostic framework enables rapid problem identification and helps determine the appropriate response. All SMA inverter series (Sunny Boy, Sunny Tripower) utilize continuous performance monitoring with real-time error detection. Error codes are typically numeric (e.g., 33, 39, 102, 202, 301, 501, 3401, 3501, 6402, 7001) that indicate specific system conditions or faults. Some codes like 33 and 39 may appear particularly in winter months and are often non-critical. Always reference your specific model's installation manual for precise code definitions.
Grid Connection Errors
Problems with AC grid voltage, frequency, and connection.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 102 | Grid Fault/Grid Overvoltage Fast - Inverter detected fast overvoltage in grid |
|
|
| 202 | Grid Fault/Grid Undervoltage Fast - Fast undervoltage in grid detected |
|
|
| 301 | Grid Fault/Voltage Increase Protection - Inverter detected unexpected voltage increase in grid |
|
|
| 501 | Grid Fault/Grid Frequency Disturbance - Grid frequency deviation from allowable range detected |
|
|
| 33 | Input Voltage Too High - Inverter recognizes input voltage is too high |
|
|
| 39 | Insufficient Conditions for Feed-in - Inverter not feeding in due to insufficient conditions |
|
|
DC Voltage and Isolation Errors
Problems with DC input voltage and electrical isolation.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 3401 | DC Overvoltage / Overvoltage Input A (SW) - Input voltage at Input A is too high |
|
|
| 3501 | Insulation Resistance / Isolation Fault - Isolation fault detected in DC circuit |
|
|
| DC Voltage Too Low | DC input voltage below minimum operating threshold |
|
|
Temperature and Overheating Errors
Problems with inverter temperature and thermal protection.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 6402 | Self-Diagnosis / Overtemperature - Inverter detected internal overheating |
|
|
| 7001 | Fault Sensor Internal Temperature - Internal temperature sensor in inverter is defective |
|
|
DC Current and Power Errors
Problems with DC current and power generation.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 6406 | DC Overcurrent / Overcurrent Input A (HW) - Too high current at Input A detected |
|
|
| No DC Power | Inverter not receiving DC power from solar panels |
|
|
Communication and Monitoring Errors
Problems with communication and monitoring systems.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| No Communication with Data Logger | Inverter cannot communicate with SMA Data Logger |
|
|
| Sunny Portal Not Accessible | Sunny Portal monitoring not accessible or showing errors |
|
|
Internal Inverter Errors
Problems with inverter internal systems and hardware.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| Internal Inverter Error | Internal inverter fault or hardware error |
|
|
| Power Stage Error | Inverter power stage fault |
|
|
Critical Safety Notice
Do not attempt DIY repairs on your SMA solar system. The majority of diagnostic codes relate to high-voltage DC and AC electrical systems, grid connection safety mechanisms, or critical safety features. Specific codes requiring immediate professional intervention include: 3501 (Isolation Fault), 6402 (Overtemperature), and 6406 (DC Overcurrent). Upon encountering these codes, immediately shut down the system if safe to do so and contact a certified SMA installer without delay.
Professional service is mandatory—contact a licensed solar installer or reach out to SMA technical support for expert assistance.
Maintenance Guidelines
Scheduled Service Requirements
- ✓Professional inspection and service annually by certified SMA installer
- ✓Monthly visual inspection of solar panels for damage or soiling
- ✓Clean panels quarterly or as needed based on local conditions
- ✓Monitor system performance daily through Sunny Portal
- ✓Check inverter status and LED indicators monthly
- ✓Verify Data Logger is online and communicating
Proactive Maintenance Strategies
- ✓Keep panels clean to maximize energy production
- ✓Trim trees and vegetation to prevent shading
- ✓Ensure adequate ventilation around inverter
- ✓Monitor production trends for early problem detection
- ✓Keep firmware updated for latest features and fixes
- ✓Review system alerts and error codes promptly
Frequently Asked Questions
What does error code 33 (Input Voltage Too High) mean?
Error code 33 indicates that the inverter recognizes the input voltage is too high. Check PV generator wiring configuration and review PV system design and sizing. Verify the number of modules per string matches inverter specifications and account for cold weather voltage rise. This may occur in winter months and is often non-critical. Contact a certified installer to verify string configuration.
What does error code 39 (Insufficient Conditions for Feed-in) mean?
Error code 39 indicates that the inverter is not feeding in due to insufficient conditions. No action is required - this is often normal in winter months. The inverter will automatically resume operation when conditions are optimal. Check solar irradiance levels and verify DC voltage is sufficient. This is typically non-critical and resolves automatically.
What should I do if I see error code 102 (Grid Overvoltage Fast)?
Error code 102 indicates that the inverter detected fast overvoltage in the grid. Do not attempt to override the safety shutdown. Check utility grid voltage with a multimeter and contact the utility company to report voltage issues. Wait for grid voltage to return to normal range. The system will automatically reconnect when voltage stabilizes. Contact a certified installer if voltage issues persist.
What does error code 3501 (Isolation Fault) mean?
Error code 3501 indicates an isolation fault detected in the DC circuit. Immediately shut down the system and do not attempt to restart until the fault is resolved. Inspect all PV module connections and junction boxes, check DC wiring for damage or water ingress, and test isolation resistance. This is a serious safety condition requiring professional diagnosis. Contact a certified SMA installer immediately.
What should I do if my inverter shows error code 6402 (Overtemperature)?
Error code 6402 indicates that the inverter detected internal overheating. Improve ventilation around the inverter, ensure it is not in direct sunlight, check that air vents are not blocked, verify adequate clearance around the inverter, and check cooling fan operation. Allow the inverter to cool down before restart. Contact an installer if temperature remains high after improving ventilation.
Can I repair my SMA system myself?
High-voltage DC and AC electrical work must exclusively be performed by licensed professionals to ensure safety compliance. Homeowners can safely perform basic tasks like cleaning panels and monitoring the Sunny Portal, but all technical repairs require certified SMA installers. Unauthorized work on electrical systems poses extreme danger and violates building codes.
How do I check if my Data Logger is working?
Check Data Logger status in the Sunny Portal. Verify the Data Logger is powered and online, check the network connection, and verify communication settings. If the Data Logger is offline, check communication wiring between the inverter and Data Logger, restart the Data Logger if needed, and contact an installer if communication cannot be restored.
How often should I clean my solar panels?
Solar panels should be cleaned quarterly or as needed based on local conditions. Panels in dusty areas or areas with heavy pollen may need more frequent cleaning. Keep panels clean to maximize energy production. Inspect panels monthly for damage or excessive soiling that may require immediate cleaning.
Need Additional Help?
Search our complete knowledge base to find detailed solutions for your specific problem.
Go to Knowledge BaseSummary
Proper interpretation of diagnostic codes is essential for effective SMA solar system troubleshooting. This comprehensive reference enables quick problem identification and guides appropriate response actions. SMA systems utilize numeric error codes displayed on inverter displays, LED status indicators, and status messages in the Sunny Portal monitoring system to indicate specific sensor and system malfunctions. Sunny Boy and Sunny Tripower inverters provide diagnostic information through error codes and monitoring systems for convenient diagnosis.
⚠️Complex diagnostic situations, especially those involving high-voltage DC and AC electrical systems and grid connection safety, require immediate professional evaluation. Critical codes demanding urgent response include: 3501 (Isolation Fault), 6402 (Overtemperature), and 6406 (DC Overcurrent). These indicators represent serious safety hazards requiring certified SMA installer response. Adherence to scheduled maintenance protocols and immediate attention to diagnostic codes extends equipment service life and minimizes long-term operational costs. Note that some codes like 33 and 39 may appear particularly in winter months and are often non-critical—always consult your specific unit's installation and service manual for precise interpretations.